Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth602mm
With control elementYes
Number of digital inputs6
Number of analogue outputs1
Number of HW-interfaces USB0
Supporting protocol for LONYes
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Number of digital outputs1
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Width595mm
Height2018mm
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP21
Mains voltage323 - 550V
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Type of converterU converter
Max. output at linear load at rated output voltage160kW
Number of interfaces PROFINET0
Number of phases output3
Mains frequency50/60 Hz
Max. output frequency320Hz
4-quadrant operation possibleYes
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)1
Max. output at quadratic load at rated output voltage200kW
Supporting protocol for PROFINET CBANo
Max. output voltage500V
Supporting protocol for Foundation FieldbusNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET IOYes
Nominal output current I2N385A
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX250A1-4A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

602mm

With control element

Number of digital inputs

6

Number of analogue outputs

1

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of digital outputs

1

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Width

595mm

Height

2018mm

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for KNX

With PC connection

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP21

Mains voltage

323 .. 550V

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Type of converter

U converter

Max. output at linear load at rated output voltage

160kW

Number of interfaces PROFINET

0

Number of phases output

3

Mains frequency

50/60 Hz

Max. output frequency

320Hz

4-quadrant operation possible

Application in industrial area permitted

Application in domestic- and commercial area permitted

Integrated breaking resistance

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

1

Max. output at quadratic load at rated output voltage

200kW

Supporting protocol for PROFINET CBA

Max. output voltage

500V

Supporting protocol for Foundation Fieldbus

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET IO

Nominal output current I2N

385A

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.