Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width595mm
Number of HW-interfaces USB0
Number of digital outputs1
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Supporting protocol for ModbusYes
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for KNXNo
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Number of HW-interfaces RS-2321
Number of analogue outputs1
With optical interfaceNo
Supporting protocol for TCP/IPYes
Depth602mm
Number of HW-interfaces other0
Number of analogue inputs2
With control elementYes
Height2018mm
Supporting protocol for LONYes
Number of digital inputs6
Type of converterU converter
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Number of phases output3
4-quadrant operation possibleYes
Supporting protocol for other bus systemsYes
Application in industrial area permittedYes
Number of phases input3
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage250kW
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Relative symmetric net frequency tolerance10%
Degree of protection (IP)IP21
Max. output at quadratic load at rated output voltage250kW
With PC connectionYes
Integrated breaking resistanceNo
Supporting protocol for Data-HighwayYes
Supporting protocol for DeviceNet SafetyNo
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Mains voltage323 - 550V
Number of interfaces PROFINET0
Max. output frequency320Hz
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Nominal output current I2N520A
Max. output voltage500V
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)1
Supporting protocol for EtherNet/IPYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX350A1-4A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

595mm

Number of HW-interfaces USB

0

Number of digital outputs

1

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Supporting protocol for Modbus

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for CAN

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

With optical interface

Supporting protocol for TCP/IP

Depth

602mm

Number of HW-interfaces other

0

Number of analogue inputs

2

With control element

Height

2018mm

Supporting protocol for LON

Number of digital inputs

6

Type of converter

U converter

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Number of phases output

3

4-quadrant operation possible

Supporting protocol for other bus systems

Application in industrial area permitted

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

250kW

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Relative symmetric net frequency tolerance

10%

Degree of protection (IP)

IP21

Max. output at quadratic load at rated output voltage

250kW

With PC connection

Integrated breaking resistance

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Mains voltage

323 .. 550V

Number of interfaces PROFINET

0

Max. output frequency

320Hz

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Nominal output current I2N

520A

Max. output voltage

500V

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

1

Supporting protocol for EtherNet/IP

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.