Technical specifications

Depth468mm
Height1155mm
With control elementYes
Width709mm
Number of digital outputs1
Number of analogue outputs1
Number of digital inputs6
Supporting protocol for LONYes
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-2321
Number of analogue inputs2
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayYes
Supporting protocol for other bus systemsYes
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Degree of protection (IP)IP21
Type of converterU converter
Number of interfaces PROFINET0
Mains voltage323 - 550V
4-quadrant operation possibleYes
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
With PC connectionYes
Supporting protocol for SERCOSNo
Number of phases output3
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Max. output frequency320Hz
Number of phases input3
Max. output at linear load at rated output voltage315kW
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage355kW
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)1
Supporting protocol for PROFIsafeNo
Nominal output current I2N650A
Supporting protocol for BACnetNo
Max. output voltage500V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX500A1-4A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

468mm

Height

1155mm

With control element

Width

709mm

Number of digital outputs

1

Number of analogue outputs

1

Number of digital inputs

6

Supporting protocol for LON

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

1

Number of analogue inputs

2

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for KNX

Degree of protection (IP)

IP21

Type of converter

U converter

Number of interfaces PROFINET

0

Mains voltage

323 .. 550V

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

With PC connection

Supporting protocol for SERCOS

Number of phases output

3

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Max. output frequency

320Hz

Number of phases input

3

Max. output at linear load at rated output voltage

315kW

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

355kW

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

1

Supporting protocol for PROFIsafe

Nominal output current I2N

650A

Supporting protocol for BACnet

Max. output voltage

500V