Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LONYes
Height56.6mm
Depth105.5mm
Number of analogue inputs2
Number of digital inputs6
Width141.6mm
Number of analogue outputs1
Number of digital outputs1
With control elementYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayYes
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other1
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Degree of protection (IP)IP00
Supporting protocol for other bus systemsYes
With PC connectionYes
Mains voltage380 - 500V
Number of phases input3
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Application in industrial area permittedYes
Type of converterU converter
Number of phases output3
Integrated breaking resistanceNo
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage900kW
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
Nominal output current I2N1770A
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Max. output at quadratic load at rated output voltage1000kW
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Max. output frequency320Hz
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Relative symmetric net frequency tolerance10%

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPXH12A0-4A2N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LON

Height

56.6mm

Depth

105.5mm

Number of analogue inputs

2

Number of digital inputs

6

Width

141.6mm

Number of analogue outputs

1

Number of digital outputs

1

With control element

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for KNX

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Number of HW-interfaces other

1

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

With optical interface

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Degree of protection (IP)

IP00

Supporting protocol for other bus systems

With PC connection

Mains voltage

380 .. 500V

Number of phases input

3

Number of interfaces PROFINET

0

4-quadrant operation possible

Application in industrial area permitted

Type of converter

U converter

Number of phases output

3

Integrated breaking resistance

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

900kW

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Nominal output current I2N

1770A

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

1000kW

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Max. output frequency

320Hz

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Relative symmetric net frequency tolerance

10%

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.