Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Height327mm
With control elementYes
Number of digital outputs1
Number of HW-interfaces RS-2321
Number of analogue outputs1
Number of digital inputs6
Number of analogue inputs2
Number of HW-interfaces RS-4220
Width128mm
Number of HW-interfaces RS-4850
Supporting protocol for LONYes
Depth190mm
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayYes
With PC connectionYes
With optical interfaceNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP21
Number of interfaces PROFINET0
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Mains frequency50/60 Hz
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
4-quadrant operation possibleYes
Supporting protocol for INTERBUSNo
Mains voltage177 - 264V
Supporting protocol for CANYes
Number of phases output3
Supporting protocol for ASINo
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage1.1kW
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Max. output voltage240V
Supporting protocol for SafetyBUS pNo
Max. output frequency320Hz
Nominal output current I2N6.6A
Number of phases input3
Supporting protocol for BACnetNo
Application in industrial area permittedYes
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)1
Integrated breaking resistanceYes
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVX001A1-2A1B2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Height

327mm

With control element

Number of digital outputs

1

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

Number of digital inputs

6

Number of analogue inputs

2

Number of HW-interfaces RS-422

0

Width

128mm

Number of HW-interfaces RS-485

0

Supporting protocol for LON

Depth

190mm

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

With PC connection

With optical interface

Supporting protocol for SUCONET

Degree of protection (IP)

IP21

Number of interfaces PROFINET

0

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Mains frequency

50/60 Hz

Supporting protocol for KNX

Supporting protocol for Modbus

4-quadrant operation possible

Supporting protocol for INTERBUS

Mains voltage

177 .. 264V

Supporting protocol for CAN

Number of phases output

3

Supporting protocol for ASI

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

1.1kW

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Max. output voltage

240V

Supporting protocol for SafetyBUS p

Max. output frequency

320Hz

Nominal output current I2N

6.6A

Number of phases input

3

Supporting protocol for BACnet

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

1

Integrated breaking resistance

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.