  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height327mm
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
Supporting protocol for LONYes
Number of HW-interfaces industrial Ethernet0
Number of digital inputs6
Depth190mm
Number of digital outputs1
Number of HW-interfaces RS-4850
Number of analogue outputs1
With control elementYes
Number of analogue inputs2
Width128mm
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
Number of HW-interfaces other0
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Supporting protocol for ASINo
Supporting protocol for Data-HighwayYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP21
Supporting protocol for SERCOSNo
Mains voltage323 - 550V
Max. output frequency320Hz
Application in industrial area permittedYes
4-quadrant operation possibleYes
Integrated breaking resistanceYes
Mains frequency50/60 Hz
Number of phases input3
Number of phases output3
Number of interfaces PROFINET0
Type of converterU converter
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage0.75kW
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET IOYes
Relative symmetric net voltage tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)1
Supporting protocol for AS-Interface Safety at WorkNo
Nominal output current I2N3.3A
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVX001A1-4A1B2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

327mm

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

6

Depth

190mm

Number of digital outputs

1

Number of HW-interfaces RS-485

0

Number of analogue outputs

1

With control element

Number of analogue inputs

2

Width

128mm

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

With PC connection

Supporting protocol for other bus systems

Degree of protection (IP)

IP21

Supporting protocol for SERCOS

Mains voltage

323 .. 550V

Max. output frequency

320Hz

Application in industrial area permitted

4-quadrant operation possible

Integrated breaking resistance

Mains frequency

50/60 Hz

Number of phases input

3

Number of phases output

3

Number of interfaces PROFINET

0

Type of converter

U converter

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

0.75kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET IO

Relative symmetric net voltage tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Degree of protection (NEMA)

1

Supporting protocol for AS-Interface Safety at Work

Nominal output current I2N

3.3A

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.