Technical specifications

Number of HW-interfaces RS-4850
Width237mm
Number of analogue outputs1
With control elementYes
Depth189mm
Number of HW-interfaces serial TTY0
Number of digital outputs1
Number of analogue inputs2
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ASINo
Supporting protocol for LONYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other0
Number of digital inputs6
Number of HW-interfaces RS-4220
With optical interfaceNo
Height630mm
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayYes
Mains voltage177 - 264V
Number of phases output3
Mains frequency50/60 Hz
With PC connectionYes
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP54
Supporting protocol for ModbusYes
Number of interfaces PROFINET0
Supporting protocol for SUCONETNo
Application in domestic- and commercial area permittedYes
Number of phases input3
Max. output at quadratic load at rated output voltage22kW
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage18.5kW
Max. output frequency320Hz
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Max. output voltage240V
Nominal output current I2N88A
Degree of protection (NEMA)12
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVX025A2-2A1N2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-485

0

Width

237mm

Number of analogue outputs

1

With control element

Depth

189mm

Number of HW-interfaces serial TTY

0

Number of digital outputs

1

Number of analogue inputs

2

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for ASI

Supporting protocol for LON

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

Number of digital inputs

6

Number of HW-interfaces RS-422

0

With optical interface

Height

630mm

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Mains voltage

177 .. 264V

Number of phases output

3

Mains frequency

50/60 Hz

With PC connection

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Degree of protection (IP)

IP54

Supporting protocol for Modbus

Number of interfaces PROFINET

0

Supporting protocol for SUCONET

Application in domestic- and commercial area permitted

Number of phases input

3

Max. output at quadratic load at rated output voltage

22kW

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Max. output at linear load at rated output voltage

18.5kW

Max. output frequency

320Hz

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Max. output voltage

240V

Nominal output current I2N

88A

Degree of protection (NEMA)

12

Supporting protocol for PROFINET CBA