Technical specifications

With control elementYes
Number of analogue inputs2
Height630mm
Number of digital outputs1
Number of analogue outputs1
Depth189mm
Number of digital inputs6
Width237mm
Supporting protocol for LONYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Supporting protocol for CANYes
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayYes
Supporting protocol for ModbusYes
Degree of protection (IP)IP54
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Number of HW-interfaces other0
Number of HW-interfaces RS-2321
Supporting protocol for ASINo
With PC connectionYes
Supporting protocol for SERCOSNo
Mains voltage323 - 550V
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of phases input3
Number of interfaces PROFINET0
Integrated breaking resistanceNo
Type of converterU converter
Application in industrial area permittedYes
Number of phases output3
Application in domestic- and commercial area permittedYes
4-quadrant operation possibleYes
Max. output frequency320Hz
Supporting protocol for PROFIsafeNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage30kW
Supporting protocol for EtherNet/IPYes
Max. output voltage500V
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage37kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N72A
Supporting protocol for BACnetNo
Degree of protection (NEMA)12
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVX040A2-4A1N2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Number of analogue inputs

2

Height

630mm

Number of digital outputs

1

Number of analogue outputs

1

Depth

189mm

Number of digital inputs

6

Width

237mm

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

Supporting protocol for TCP/IP

Supporting protocol for CAN

With optical interface

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Degree of protection (IP)

IP54

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

1

Supporting protocol for ASI

With PC connection

Supporting protocol for SERCOS

Mains voltage

323 .. 550V

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of phases input

3

Number of interfaces PROFINET

0

Integrated breaking resistance

Type of converter

U converter

Application in industrial area permitted

Number of phases output

3

Application in domestic- and commercial area permitted

4-quadrant operation possible

Max. output frequency

320Hz

Supporting protocol for PROFIsafe

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

30kW

Supporting protocol for EtherNet/IP

Max. output voltage

500V

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

37kW

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Nominal output current I2N

72A

Supporting protocol for BACnet

Degree of protection (NEMA)

12