Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Width237mm
Height630mm
Depth189mm
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPYes
Number of analogue inputs2
Number of HW-interfaces USB0
Number of digital outputs1
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of analogue outputs1
Number of HW-interfaces other0
Number of HW-interfaces RS-2321
Supporting protocol for ASINo
Number of digital inputs6
Supporting protocol for LONYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayYes
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Mains voltage323 - 550V
With PC connectionYes
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage45kW
Max. output at quadratic load at rated output voltage55kW
Type of converterU converter
Degree of protection (IP)IP54
Supporting protocol for SERCOSNo
Number of phases input3
Max. output frequency320Hz
Mains frequency50/60 Hz
Application in industrial area permittedYes
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Nominal output current I2N105A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVX060A2-4A1N2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Width

237mm

Height

630mm

Depth

189mm

Number of HW-interfaces industrial Ethernet

0

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Number of analogue inputs

2

Number of HW-interfaces USB

0

Number of digital outputs

1

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of analogue outputs

1

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

1

Supporting protocol for ASI

Number of digital inputs

6

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Number of interfaces PROFINET

0

4-quadrant operation possible

Mains voltage

323 .. 550V

With PC connection

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output at linear load at rated output voltage

45kW

Max. output at quadratic load at rated output voltage

55kW

Type of converter

U converter

Degree of protection (IP)

IP54

Supporting protocol for SERCOS

Number of phases input

3

Max. output frequency

320Hz

Mains frequency

50/60 Hz

Application in industrial area permitted

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

105A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.