Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Width128mm
With control elementYes
Depth190mm
Height327mm
Number of digital outputs1
Number of digital inputs6
Number of HW-interfaces RS-2321
Number of analogue outputs1
Supporting protocol for LONYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Supporting protocol for TCP/IPYes
Supporting protocol for other bus systemsYes
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for Data-HighwayYes
Number of HW-interfaces parallel0
Supporting protocol for ModbusYes
With PC connectionYes
Mains frequency50/60 Hz
Degree of protection (IP)IP21
Number of HW-interfaces RS-4220
Supporting protocol for KNXNo
Number of HW-interfaces other0
4-quadrant operation possibleYes
Supporting protocol for INTERBUS-SafetyNo
Mains voltage177 - 264V
Max. output at linear load at rated output voltage1.1kW
Application in domestic- and commercial area permittedYes
Max. output frequency320Hz
Number of phases output3
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage1.5kW
Type of converterU converter
Supporting protocol for Foundation FieldbusNo
Number of interfaces PROFINET0
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Number of phases input3
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Application in industrial area permittedYes
Integrated breaking resistanceYes
Relative symmetric net frequency tolerance10%
Nominal output current I2N7.8A
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)1
Max. output voltage240V
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

SVXF15A1-2A1B2

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Width

128mm

With control element

Depth

190mm

Height

327mm

Number of digital outputs

1

Number of digital inputs

6

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for ASI

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Data-Highway

Number of HW-interfaces parallel

0

Supporting protocol for Modbus

With PC connection

Mains frequency

50/60 Hz

Degree of protection (IP)

IP21

Number of HW-interfaces RS-422

0

Supporting protocol for KNX

Number of HW-interfaces other

0

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Mains voltage

177 .. 264V

Max. output at linear load at rated output voltage

1.1kW

Application in domestic- and commercial area permitted

Max. output frequency

320Hz

Number of phases output

3

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

1.5kW

Type of converter

U converter

Supporting protocol for Foundation Fieldbus

Number of interfaces PROFINET

0

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Number of phases input

3

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Application in industrial area permitted

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Nominal output current I2N

7.8A

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

1

Max. output voltage

240V

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.