Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as safety switch
No
Version as emergency stop installation
No
Version as maintenance-/service switch
Yes
Number of switches
1
Version as main switch
Yes
Rated operating voltage
690 - 690V
Max. rated operation voltage Ue AC
690V
Version as reversing switch
No
Rated permanent current Iu
20A
Rated short-time withstand current lcw
0.32kA
Rated operation power at AC-23, 400 V
5.5kW
Rated permanent current at AC-23, 400 V
13.3A
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as change-over contact
0
Number of poles
2
Number of auxiliary contacts as normally closed contact
0
Suitable for front mounting 4-hole
No
Voltage release optional
No
Interlockable
Yes
Suitable for distribution board installation
No
Type of electrical connection of main circuit
Screw connection
Motor drive optional
No
Degree of protection (NEMA)
12
Suitable for floor mounting
Yes
Colour control element
Black
Type of control element
Door coupling rotary drive
Width
150mm
Degree of protection (IP), front side
IP65
With pre-assembled cabling
No
Device construction
Complete device in housing
Height
135mm
Suitable for front mounting centre
No
Suitable for intermediate mounting
No
Switching power at 400 V
5.5kW
Number of auxiliary contacts as normally open contact
0
Depth
200mm
Motor drive integrated
No
T0-1-102/SE1/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as safety switch
Version as emergency stop installation
Version as maintenance-/service switch
Number of switches
1
Version as main switch
Rated operating voltage
690 .. 690V
Max. rated operation voltage Ue AC
690V
Version as reversing switch
Rated permanent current Iu
20A
Rated short-time withstand current lcw
0.32kA
Rated operation power at AC-23, 400 V
5.5kW
Rated permanent current at AC-23, 400 V
13.3A
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as change-over contact
0
Number of poles
2
Number of auxiliary contacts as normally closed contact
0
Suitable for front mounting 4-hole
Voltage release optional
Interlockable
Suitable for distribution board installation
Type of electrical connection of main circuit
Screw connection
Motor drive optional
Degree of protection (NEMA)
12
Suitable for floor mounting
Colour control element
Black
Type of control element
Door coupling rotary drive
Width
150mm
Degree of protection (IP), front side
IP65
With pre-assembled cabling
Device construction
Complete device in housing
Height
135mm
Suitable for front mounting centre
Suitable for intermediate mounting
Switching power at 400 V
5.5kW
Number of auxiliary contacts as normally open contact
0
Depth
200mm
Motor drive integrated
We use cookies to enhance your experience.