Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •EATON
Technical specifications
XC-303-C21-001

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- EATON
Technical specifications
Model
Modular
Width
85mm
Number of digital inputs
0
Height
65mm
Number of digital outputs
0
With display
Suitable for safety functions
Depth
108mm
Voltage type of supply voltage
DC
Type of memory
RAM
Number of analogue inputs
0
Number of analogue outputs
0
Processing time (1K, binary operation)
0.001ms
Memory size
512000kByte
Supporting protocol for LON
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
1
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
With optical interface
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Redundancy
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for other bus systems
Explosion safety category for gas
None
Appendant operation agent (Ex ia)
Rail mounting possible
Explosion safety category for dust
None
System accessory
Supporting protocol for INTERBUS-Safety
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Additional program memory possible
Number of HW-interfaces Wireless
0
Wall mounting/direct mounting
Radio standard Bluetooth
IO link master
Front built-in possible
Number of relay outputs
0
Rack-assembly possible
Radio standard Wi-Fi 802.11
Performance level according to EN ISO 13849-1
None
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Max. number of time switches
1000
Supporting protocol for PROFINET IO
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET CBA
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage DC
18 .. 30V
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for PROFIsafe
Radio standard GPRS
Radio standard UMTS
Long-Term Evolution (LTE)
Radio standard GSM
SIL according to IEC 61508
None
Certified for UL hazardous location class III
Certified for UL hazardous location class II
Certified for UL hazardous location class I
Supporting protocol for DNP3
Supporting protocol for EtherCAT
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for IEC 60870
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group G (non-conductive dusts)