Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - analogue I/O module
- •1 KOM
- •EATON
Technical specifications
Width12.6mm
Height74.1mm
Depth55.4mm
Suitable for safety functionsNo
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Input, currentYes
Input, voltageNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableYes
Output, currentNo
Output, voltageNo
Output signal configurableNo
Type of electric connectionScrew-/spring clamp connection
Rail mounting possibleYes
Explosion safety category for gasNone
Explosion safety category for dustNone
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
IO link masterNo
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC20.4 - 28.8V
Analogue inputs configurableYes
Analogue outputs configurableYes
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
SIL according to IEC 61508None
Degree of protection (NEMA)1
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Number of analogue inputs2
Number of analogue outputs0
Voltage type of supply voltageDC
Resolution of the analogue inputs16Bit
Resolution of the analogue outputs0Bit