Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - analogue I/O module
- •1 KOM
- •EATON
Technical specifications
XN-2AI-I(0/4...20MA)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue I/O module
- 1 KOM
- EATON
Technical specifications
Width
12.6mm
Height
74.1mm
Depth
55.4mm
Suitable for safety functions
Number of analogue inputs
2
Number of analogue outputs
0
Voltage type of supply voltage
DC
Supporting protocol for LON
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for other bus systems
Input, current
Input, voltage
Input, resistor
Input, resistance thermometer
Input, thermocouple
Input signal, configurable
Output, current
Output, voltage
Output signal configurable
Resolution of the analogue inputs
16Bit
Resolution of the analogue outputs
0Bit
Type of electric connection
Screw-/spring clamp connection
Rail mounting possible
Explosion safety category for gas
None
Explosion safety category for dust
None
Fieldbus connection over separate bus coupler possible
System accessory
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Number of interfaces PROFINET
0
Number of HW-interfaces Wireless
0
Front built-in possible
Rack-assembly possible
Wall mounting/direct mounting
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
IO link master
Performance level according to EN ISO 13849-1
None
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
20.4 .. 28.8V
Analogue inputs configurable
Analogue outputs configurable
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
SIL according to IEC 61508
None
Degree of protection (NEMA)
1
Supporting protocol for EtherCAT
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)