Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functionsNo
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Height74.1mm
Number of HW-interfaces serial TTY0
Depth55.4mm
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4850
Number of HW-interfaces other1
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Supporting protocol for ASINo
Width12.6mm
Supporting protocol for ModbusNo
Appendant operation agent (Ex ia)No
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Appendant operation agent (Ex ib)No
Input, voltageYes
Output, voltageNo
Output signal configurableNo
Input signal, configurableYes
Explosion safety category for dustNone
Input, resistorNo
Input, thermocoupleNo
System accessoryYes
Rail mounting possibleYes
Supporting protocol for DeviceNetNo
Fieldbus connection over separate bus coupler possibleYes
Type of electric connectionScrew-/spring clamp connection
Input, currentNo
Output, currentNo
Explosion safety category for gasNone
Input, resistance thermometerNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Supply voltage AC 50 Hz0 - 0V
Radio standard GPRSNo
Supporting protocol for EtherNet/IPNo
Number of HW-interfaces Wireless0
IO link masterNo
Supporting protocol for DeviceNet SafetyNo
Analogue inputs configurableYes
Supporting protocol for PROFINET CBANo
Wall mounting/direct mountingNo
Supporting protocol for PROFINET IONo
Supply voltage DC20.4 - 28.8V
Supporting protocol for PROFIsafeNo
Performance level according to EN ISO 13849-1None
Analogue outputs configurableYes
Supporting protocol for SafetyBUS pNo
Supply voltage AC 60 Hz0 - 0V
Rack-assembly possibleNo
Supporting protocol for Foundation FieldbusNo
Front built-in possibleNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for INTERBUS-SafetyNo
Radio standard GSMNo
Supporting protocol for AS-Interface Safety at WorkNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group B (hydrogen)No
SIL according to IEC 61508None
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 2No
Radio standard UMTSNo
Certified for UL hazardous location class IINo
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location group C (ethylene)No
Degree of protection (NEMA)1
Certified for UL hazardous location group G (non-conductive dusts)No
Number of analogue inputs2
Number of analogue outputs0
Voltage type of supply voltageDC
Resolution of the analogue inputs16Bit
Resolution of the analogue outputs0Bit
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user