Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - analogue I/O module
- •1 KOM
- •EATON
Technical specifications
XN-2AO-U(-10/0...+10VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue I/O module
- 1 KOM
- EATON
Technical specifications
Suitable for safety functions
Depth
55.4mm
Height
74.1mm
Width
12.6mm
Number of analogue inputs
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for LON
Number of analogue outputs
2
Input, current
Voltage type of supply voltage
DC
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
0
Supporting protocol for DeviceNet
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for Modbus
Number of HW-interfaces RS-485
0
Supporting protocol for INTERBUS
Number of HW-interfaces serial TTY
0
Supporting protocol for TCP/IP
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces other
1
Input, voltage
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for SUCONET
Number of HW-interfaces USB
0
Input signal, configurable
Input, resistor
Type of electric connection
Screw-/spring clamp connection
Output, current
Explosion safety category for gas
None
Output signal configurable
Input, resistance thermometer
Supporting protocol for SERCOS
Resolution of the analogue outputs
16Bit
System accessory
Input, thermocouple
Explosion safety category for dust
None
Degree of protection (IP)
IP20
Rail mounting possible
Fieldbus connection over separate bus coupler possible
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Resolution of the analogue inputs
0Bit
Output, voltage
Number of interfaces PROFINET
0
Rack-assembly possible
Wall mounting/direct mounting
Front built-in possible
Number of HW-interfaces Wireless
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
IO link master
Analogue outputs configurable
Radio standard Wi-Fi 802.11
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Performance level according to EN ISO 13849-1
None
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Radio standard GPRS
Certified for UL hazardous location class II
Supply voltage DC
20.4 .. 28.8V
Radio standard UMTS
Degree of protection (NEMA)
1
Supporting protocol for EtherCAT
Supply voltage AC 60 Hz
0 .. 0V
Analogue inputs configurable
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supply voltage AC 50 Hz
0 .. 0V
Certified for UL hazardous location class I
Supporting protocol for EtherNet/IP
Radio standard GSM
SIL according to IEC 61508
None
Radio standard Bluetooth
Certified for UL hazardous location class III
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group A (acetylene)