Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Height74.1mm
Depth55.4mm
Width12.6mm
Suitable for safety functionsNo
Input current at signal 10mA
Number of digital inputs0
Number of digital outputs2
Number of HW-interfaces USB0
Supporting protocol for ModbusNo
Time delay at signal exchange10 - 11ms
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4850
Supporting protocol for INTERBUSNo
Voltage type of supply voltageAC
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Number of HW-interfaces other1
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Number of HW-interfaces parallel0
Type of voltage (input voltage)AC
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of interfaces PROFINET0
Front built-in possibleNo
Short-circuit protection, outputs availableNo
Appendant operation agent (Ex ia)No
Supporting protocol for AS-Interface Safety at WorkNo
Type of electric connectionScrew-/spring clamp connection
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ib)No
System accessoryYes
Fieldbus connection over separate bus coupler possibleYes
Radio standard Wi-Fi 802.11No
IO link masterNo
Supporting protocol for SERCOSNo
Performance level according to EN ISO 13849-1None
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Rail mounting possibleYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Type of digital outputTriac
Output current0.5A
Explosion safety category for gasNone
Rack-assembly possibleNo
Explosion safety category for dustNone
Wall mounting/direct mountingNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supply voltage AC 50 Hz102 - 253V
Radio standard GPRSNo
Supporting protocol for SafetyBUS pNo
Certified for UL hazardous location division 2No
Permitted voltage at output0 - 250V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Certified for UL hazardous location division 1No
Radio standard UMTSNo
Certified for UL hazardous location class IINo
Supporting protocol for EtherNet/IPNo
Permitted voltage at input0 - 0V
Digital inputs configurableNo
Radio standard GSMNo
Certified for UL hazardous location class INo
Supply voltage DC0 - 0V
Digital outputs configurableNo
Supporting protocol for PROFINET CBANo
Supply voltage AC 60 Hz102 - 253V
Supporting protocol for EtherCATNo
Certified for UL hazardous location class IIINo
SIL according to IEC 61508None
Type of output voltageAC
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group G (non-conductive dusts)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XN-2DO-120/230VAC-0.5A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Height

74.1mm

Depth

55.4mm

Width

12.6mm

Suitable for safety functions

Input current at signal 1

0mA

Number of digital inputs

0

Number of digital outputs

2

Number of HW-interfaces USB

0

Supporting protocol for Modbus

Time delay at signal exchange

10 .. 11ms

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Supporting protocol for INTERBUS

Voltage type of supply voltage

AC

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for CAN

Number of HW-interfaces other

1

Supporting protocol for KNX

Supporting protocol for Data-Highway

Number of HW-interfaces RS-232

0

Supporting protocol for ASI

Supporting protocol for DeviceNet

Number of HW-interfaces parallel

0

Type of voltage (input voltage)

AC

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Front built-in possible

Short-circuit protection, outputs available

Appendant operation agent (Ex ia)

Supporting protocol for AS-Interface Safety at Work

Type of electric connection

Screw-/spring clamp connection

Number of HW-interfaces Wireless

0

Appendant operation agent (Ex ib)

System accessory

Fieldbus connection over separate bus coupler possible

Radio standard Wi-Fi 802.11

IO link master

Supporting protocol for SERCOS

Performance level according to EN ISO 13849-1

None

Supporting protocol for other bus systems

Radio standard Bluetooth

Rail mounting possible

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Type of digital output

Triac

Output current

0.5A

Explosion safety category for gas

None

Rack-assembly possible

Explosion safety category for dust

None

Wall mounting/direct mounting

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supply voltage AC 50 Hz

102 .. 253V

Radio standard GPRS

Supporting protocol for SafetyBUS p

Certified for UL hazardous location division 2

Permitted voltage at output

0 .. 250V

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Certified for UL hazardous location division 1

Radio standard UMTS

Certified for UL hazardous location class II

Supporting protocol for EtherNet/IP

Permitted voltage at input

0 .. 0V

Digital inputs configurable

Radio standard GSM

Certified for UL hazardous location class I

Supply voltage DC

0 .. 0V

Digital outputs configurable

Supporting protocol for PROFINET CBA

Supply voltage AC 60 Hz

102 .. 253V

Supporting protocol for EtherCAT

Certified for UL hazardous location class III

SIL according to IEC 61508

None

Type of output voltage

AC

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group G (non-conductive dusts)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.