Technical specifications

Width12.6mm
Input current at signal 10mA
Number of HW-interfaces industrial Ethernet0
Voltage type of supply voltageAC/DC
Number of HW-interfaces RS-4850
Height74.1mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Time delay at signal exchange0 - 0ms
Number of digital outputs2
Number of digital inputs0
Suitable for safety functionsNo
Depth55.4mm
Number of HW-interfaces RS-2320
Type of voltage (input voltage)AC/DC
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Number of HW-interfaces other1
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for ModbusNo
Type of electric connectionScrew-/spring clamp connection
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Short-circuit protection, outputs availableNo
Output current5A
Supporting protocol for other bus systemsYes
Rail mounting possibleYes
Type of digital outputRelay
Explosion safety category for gasNone
Supporting protocol for INTERBUSNo
Explosion safety category for dustNone
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Degree of protection (IP)IP20
System accessoryYes
Radio standard Wi-Fi 802.11No
Supporting protocol for DeviceNet SafetyNo
IO link masterNo
Supporting protocol for PROFINET CBANo
Wall mounting/direct mountingNo
Number of HW-interfaces Wireless0
Supporting protocol for PROFINET IONo
Radio standard BluetoothNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of output voltageAC/DC
Supply voltage DC18 - 30V
Permitted voltage at input0 - 0V
Supporting protocol for Foundation FieldbusNo
Front built-in possibleNo
Supporting protocol for PROFIsafeNo
Permitted voltage at output0 - 0V
Performance level according to EN ISO 13849-1None
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Rack-assembly possibleNo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for EtherNet/IPNo
Radio standard GPRSNo
Digital outputs configurableNo
Digital inputs configurableNo
Supporting protocol for EtherCATNo
SIL according to IEC 61508None
Radio standard UMTSNo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location division 2No
Radio standard GSMNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group D (propane)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XN-2DO-R-CO

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Width

12.6mm

Input current at signal 1

0mA

Number of HW-interfaces industrial Ethernet

0

Voltage type of supply voltage

AC/DC

Number of HW-interfaces RS-485

0

Height

74.1mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Time delay at signal exchange

0 .. 0ms

Number of digital outputs

2

Number of digital inputs

0

Suitable for safety functions

Depth

55.4mm

Number of HW-interfaces RS-232

0

Type of voltage (input voltage)

AC/DC

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

With optical interface

Supporting protocol for Modbus

Type of electric connection

Screw-/spring clamp connection

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for DeviceNet

Short-circuit protection, outputs available

Output current

5A

Supporting protocol for other bus systems

Rail mounting possible

Type of digital output

Relay

Explosion safety category for gas

None

Supporting protocol for INTERBUS

Explosion safety category for dust

None

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Fieldbus connection over separate bus coupler possible

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Degree of protection (IP)

IP20

System accessory

Radio standard Wi-Fi 802.11

Supporting protocol for DeviceNet Safety

IO link master

Supporting protocol for PROFINET CBA

Wall mounting/direct mounting

Number of HW-interfaces Wireless

0

Supporting protocol for PROFINET IO

Radio standard Bluetooth

Supporting protocol for AS-Interface Safety at Work

Type of output voltage

AC/DC

Supply voltage DC

18 .. 30V

Permitted voltage at input

0 .. 0V

Supporting protocol for Foundation Fieldbus

Front built-in possible

Supporting protocol for PROFIsafe

Permitted voltage at output

0 .. 0V

Performance level according to EN ISO 13849-1

None

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for SafetyBUS p

Rack-assembly possible

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for EtherNet/IP

Radio standard GPRS

Digital outputs configurable

Digital inputs configurable

Supporting protocol for EtherCAT

SIL according to IEC 61508

None

Radio standard UMTS

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location class I

Certified for UL hazardous location division 2

Radio standard GSM

Certified for UL hazardous location division 1

Certified for UL hazardous location class II

Certified for UL hazardous location class III

Certified for UL hazardous location group D (propane)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.