  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functionsNo
Depth55.4mm
Input current at signal 10mA
Width12.6mm
Height74.1mm
Voltage type of supply voltageAC/DC
Number of digital outputs2
Time delay at signal exchange0 - 0ms
Number of digital inputs0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of HW-interfaces RS-4850
Number of HW-interfaces industrial Ethernet0
Supporting protocol for other bus systemsYes
Type of voltage (input voltage)AC/DC
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Short-circuit protection, outputs availableNo
With optical interfaceNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Output current5A
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces other1
Supporting protocol for PROFIBUSNo
Type of digital outputRelay
Type of electric connectionScrew-/spring clamp connection
Rail mounting possibleYes
IO link masterNo
Appendant operation agent (Ex ib)No
Number of interfaces PROFINET0
Appendant operation agent (Ex ia)No
Wall mounting/direct mountingNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Explosion safety category for gasNone
Fieldbus connection over separate bus coupler possibleYes
Front built-in possibleNo
Explosion safety category for dustNone
Degree of protection (IP)IP20
System accessoryYes
Performance level according to EN ISO 13849-1None
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces Wireless0
Rack-assembly possibleNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Radio standard GPRSNo
Certified for UL hazardous location class IINo
Digital inputs configurableNo
Supply voltage DC18 - 30V
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 2No
Supply voltage AC 60 Hz0 - 0V
Certified for UL hazardous location class IIINo
Permitted voltage at output0 - 250V
Certified for UL hazardous location class INo
Supporting protocol for EtherCATNo
Digital outputs configurableNo
Supporting protocol for PROFIsafeNo
Permitted voltage at input0 - 0V
Radio standard UMTSNo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Certified for UL hazardous location division 1No
SIL according to IEC 61508None
Radio standard GSMNo
Type of output voltageAC/DC
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XN-2DO-R-NO

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functions

Depth

55.4mm

Input current at signal 1

0mA

Width

12.6mm

Height

74.1mm

Voltage type of supply voltage

AC/DC

Number of digital outputs

2

Time delay at signal exchange

0 .. 0ms

Number of digital inputs

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces RS-485

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for other bus systems

Type of voltage (input voltage)

AC/DC

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Short-circuit protection, outputs available

With optical interface

Supporting protocol for KNX

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Output current

5A

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for INTERBUS

Number of HW-interfaces other

1

Supporting protocol for PROFIBUS

Type of digital output

Relay

Type of electric connection

Screw-/spring clamp connection

Rail mounting possible

IO link master

Appendant operation agent (Ex ib)

Number of interfaces PROFINET

0

Appendant operation agent (Ex ia)

Wall mounting/direct mounting

Radio standard Bluetooth

Radio standard Wi-Fi 802.11

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Explosion safety category for gas

None

Fieldbus connection over separate bus coupler possible

Front built-in possible

Explosion safety category for dust

None

Degree of protection (IP)

IP20

System accessory

Performance level according to EN ISO 13849-1

None

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces Wireless

0

Rack-assembly possible

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Radio standard GPRS

Certified for UL hazardous location class II

Digital inputs configurable

Supply voltage DC

18 .. 30V

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location division 2

Supply voltage AC 60 Hz

0 .. 0V

Certified for UL hazardous location class III

Permitted voltage at output

0 .. 250V

Certified for UL hazardous location class I

Supporting protocol for EtherCAT

Digital outputs configurable

Supporting protocol for PROFIsafe

Permitted voltage at input

0 .. 0V

Radio standard UMTS

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Certified for UL hazardous location division 1

SIL according to IEC 61508

None

Radio standard GSM

Type of output voltage

AC/DC

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.