Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Width80.3mm
Height16.8mm
Depth104.2mm
Number of digital inputs8
Number of digital outputs8
Time delay at signal exchange0 - 0ms
Input current at signal 13.7mA
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Voltage type of supply voltageDC
Suitable for safety functionsNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4850
With optical interfaceNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces USB0
Type of voltage (input voltage)DC
Number of HW-interfaces other1
Type of digital outputTransistor
Explosion safety category for gasNone
Output current0.5A
Type of electric connectionPlug-in connection
Supporting protocol for SUCONETNo
Short-circuit protection, outputs availableYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
IO link masterNo
Fieldbus connection over separate bus coupler possibleYes
Explosion safety category for dustNone
Wall mounting/direct mountingNo
Degree of protection (IP)IP20
Front built-in possibleNo
Radio standard BluetoothNo
Appendant operation agent (Ex ia)No
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ib)No
System accessoryYes
Rack-assembly possibleNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Digital inputs configurableYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Permitted voltage at input0 - 30V
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for PROFINET IONo
SIL according to IEC 61508None
Supporting protocol for AS-Interface Safety at WorkNo
Permitted voltage at output0 - 30V
Performance level according to EN ISO 13849-1None
Supporting protocol for DeviceNet SafetyNo
Radio standard UMTSNo
Supporting protocol for PROFIsafeNo
Digital outputs configurableNo
Supply voltage AC 60 Hz0 - 0V
Radio standard GPRSNo
Type of output voltageDC
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Radio standard GSMNo
Supporting protocol for Foundation FieldbusNo
Supply voltage DC18 - 30V
Certified for UL hazardous location division 1No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group E (metal dusts)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XN-322-16DIO-PC05

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Width

80.3mm

Height

16.8mm

Depth

104.2mm

Number of digital inputs

8

Number of digital outputs

8

Time delay at signal exchange

0 .. 0ms

Input current at signal 1

3.7mA

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Voltage type of supply voltage

DC

Suitable for safety functions

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

0

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Type of voltage (input voltage)

DC

Number of HW-interfaces other

1

Type of digital output

Transistor

Explosion safety category for gas

None

Output current

0.5A

Type of electric connection

Plug-in connection

Supporting protocol for SUCONET

Short-circuit protection, outputs available

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Rail mounting possible

IO link master

Fieldbus connection over separate bus coupler possible

Explosion safety category for dust

None

Wall mounting/direct mounting

Degree of protection (IP)

IP20

Front built-in possible

Radio standard Bluetooth

Appendant operation agent (Ex ia)

Number of interfaces PROFINET

0

Number of HW-interfaces Wireless

0

Appendant operation agent (Ex ib)

System accessory

Rack-assembly possible

Radio standard Wi-Fi 802.11

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Digital inputs configurable

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Permitted voltage at input

0 .. 30V

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for PROFINET IO

SIL according to IEC 61508

None

Supporting protocol for AS-Interface Safety at Work

Permitted voltage at output

0 .. 30V

Performance level according to EN ISO 13849-1

None

Supporting protocol for DeviceNet Safety

Radio standard UMTS

Supporting protocol for PROFIsafe

Digital outputs configurable

Supply voltage AC 60 Hz

0 .. 0V

Radio standard GPRS

Type of output voltage

DC

Supporting protocol for EtherCAT

Certified for UL hazardous location class I

Certified for UL hazardous location class II

Certified for UL hazardous location class III

Radio standard GSM

Supporting protocol for Foundation Fieldbus

Supply voltage DC

18 .. 30V

Certified for UL hazardous location division 1

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location division 2

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group E (metal dusts)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.