Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
XN-322-16DI-PD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Depth
104.2mm
Height
16.8mm
Width
80.3mm
Input current at signal 1
3.7mA
Voltage type of supply voltage
DC
Number of HW-interfaces RS-232
0
Supporting protocol for TCP/IP
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for ASI
Supporting protocol for CAN
With optical interface
Supporting protocol for PROFIBUS
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Number of digital inputs
16
Number of HW-interfaces other
1
Number of HW-interfaces serial TTY
0
Suitable for safety functions
Supporting protocol for LON
Number of digital outputs
0
Number of HW-interfaces RS-422
0
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Number of HW-interfaces USB
0
Supporting protocol for INTERBUS
Type of voltage (input voltage)
DC
Supporting protocol for KNX
Time delay at signal exchange
4 .. 6ms
Type of electric connection
Plug-in connection
Front built-in possible
Rack-assembly possible
IO link master
Supporting protocol for DeviceNet
Rail mounting possible
Fieldbus connection over separate bus coupler possible
Wall mounting/direct mounting
Degree of protection (IP)
IP20
Output current
0A
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Number of interfaces PROFINET
0
Short-circuit protection, outputs available
Supporting protocol for INTERBUS-Safety
Radio standard Wi-Fi 802.11
Radio standard Bluetooth
Number of HW-interfaces Wireless
0
Appendant operation agent (Ex ia)
Explosion safety category for dust
None
Explosion safety category for gas
None
System accessory
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Type of digital output
None
Supply voltage AC 50 Hz
0 .. 0V
Permitted voltage at output
0 .. 0V
Supporting protocol for Foundation Fieldbus
Permitted voltage at input
0 .. 30V
Digital inputs configurable
Type of output voltage
DC
Radio standard GSM
Supporting protocol for AS-Interface Safety at Work
Supply voltage DC
18 .. 30V
Supporting protocol for PROFIsafe
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for PROFINET CBA
Performance level according to EN ISO 13849-1
None
Supporting protocol for PROFINET IO
Radio standard UMTS
Supporting protocol for SafetyBUS p
Supporting protocol for EtherCAT
Supporting protocol for DeviceNet Safety
Digital outputs configurable
Supporting protocol for EtherNet/IP
Certified for UL hazardous location class I
Radio standard GPRS
Certified for UL hazardous location class III
Certified for UL hazardous location class II
SIL according to IEC 61508
None
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)