Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - power module, motor switch
- •1 KOM
- •EATON
Technical specifications
XN-322-1DCD-B35

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power module, motor switch
- 1 KOM
- EATON
Technical specifications
Width
80.3mm
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces RS-232
0
Number of inputs
0
Suitable for safety functions
Number of HW-interfaces serial TTY
0
Depth
104.2mm
Height
16.8mm
Supporting protocol for ASI
With optical interface
Supporting protocol for LON
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Type of voltage (input voltage)
DC
Voltage type of supply voltage
DC
Supporting protocol for TCP/IP
Number of HW-interfaces other
1
Number of HW-interfaces RS-422
0
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for SUCONET
Type of electrical connection at the motor output
Plug-in connection
Type of electric connection
Plug-in connection
Type of digital output
Transistor
Rail mounting possible
Fieldbus connection over separate bus coupler possible
Short-circuit protection, outputs available
Supporting protocol for other bus systems
Explosion safety category for gas
None
Explosion safety category for dust
None
With brake output
Number of motor outlets
1
Supporting protocol for INTERBUS-Safety
Degree of protection (IP)
IP20
Appendant operation agent (Ex ia)
With thermal motor protection
Rated operation current of the motor
0 .. 3.5A
Supporting protocol for SERCOS
System accessory
Number of interfaces PROFINET
0
With motor current parameter setting
Appendant operation agent (Ex ib)
Number of HW-interfaces Wireless
0
Front built-in possible
Rack-assembly possible
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Performance level according to EN ISO 13849-1
None
Supporting protocol for Foundation Fieldbus
IO link master
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Wall mounting/direct mounting
Supporting protocol for PROFINET IO
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Type of output voltage
DC
Supply voltage DC
18 .. 30V
Supply voltage AC 50 Hz
0 .. 0V
Radio standard GPRS
Permitted voltage at output
12 .. 30V
Permitted voltage at input
0 .. 0V
Supporting protocol for EtherCAT
SIL according to IEC 61508
None
Radio standard UMTS
Degree of protection (NEMA)
1
Radio standard GSM
Certified for UL hazardous location division 2
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location division 1
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location class III
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)