Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Width80.3mm
Height16.8mm
Depth104.2mm
Time delay at signal exchange0 - 0ms
Number of HW-interfaces RS-2320
Suitable for safety functionsNo
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4850
Input current at signal 13.7mA
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Type of voltage (input voltage)DC
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for CANNo
With optical interfaceNo
Supporting protocol for KNXNo
Number of HW-interfaces other1
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ib)No
Short-circuit protection, outputs availableYes
Explosion safety category for dustNone
Supporting protocol for DeviceNetNo
System accessoryYes
Explosion safety category for gasNone
Type of digital outputTransistor
Output current0.5A
Type of electric connectionPlug-in connection
Supporting protocol for SUCONETNo
Rail mounting possibleYes
Appendant operation agent (Ex ia)No
Radio standard BluetoothNo
Number of HW-interfaces Wireless0
Supporting protocol for INTERBUS-SafetyNo
Rack-assembly possibleNo
Front built-in possibleNo
Wall mounting/direct mountingNo
IO link masterNo
Supporting protocol for SERCOSNo
Radio standard Wi-Fi 802.11No
Number of interfaces PROFINET0
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Performance level according to EN ISO 13849-1None
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Digital outputs configurableNo
Permitted voltage at input0 - 30V
Supply voltage AC 60 Hz0 - 0V
Permitted voltage at output0 - 30V
Certified for UL hazardous location class IINo
Radio standard GSMNo
Certified for UL hazardous location class INo
SIL according to IEC 61508None
Digital inputs configurableNo
Type of output voltageDC
Supply voltage DC18 - 30V
Radio standard GPRSNo
Radio standard UMTSNo
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Number of digital inputs4
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP20