Technical specifications

Input current at signal 12mA
Depth74.1mm
Suitable for safety functionsNo
Time delay at signal exchange0.1 - 0.3ms
Height55.4mm
Width12.6mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Type of voltage (input voltage)DC
Supporting protocol for ASINo
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Supporting protocol for KNXNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Output current0A
Short-circuit protection, outputs availableNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Explosion safety category for gasNone
Rail mounting possibleYes
Type of electric connectionScrew-/spring clamp connection
Type of digital outputNone
Number of HW-interfaces Wireless0
Number of interfaces PROFINET0
System accessoryYes
Appendant operation agent (Ex ia)No
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ib)No
Supporting protocol for SERCOSNo
Front built-in possibleNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Rack-assembly possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Performance level according to EN ISO 13849-1None
Supporting protocol for EtherNet/IPNo
IO link masterNo
Supporting protocol for INTERBUS-SafetyNo
Explosion safety category for dustNone
Wall mounting/direct mountingNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supply voltage DC18 - 30V
Permitted voltage at input0 - 30V
Type of output voltageDC
Permitted voltage at output0 - 0V
Supply voltage AC 60 Hz0 - 0V
Digital outputs configurableNo
Supply voltage AC 50 Hz0 - 0V
Digital inputs configurableNo
Radio standard GPRSNo
Certified for UL hazardous location division 2No
Supporting protocol for EtherCATNo
SIL according to IEC 61508None
Certified for UL hazardous location class IINo
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 1No
Radio standard UMTSNo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location class INo
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group B (hydrogen)No
Radio standard GSMNo
Certified for UL hazardous location group G (non-conductive dusts)No
Number of digital inputs4
Number of digital outputs0
Voltage type of supply voltageDC
Degree of protection (IP)IP20