Aleta.hr

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth25mm
Power consumption5W
Suitable for safety functionsNo
Operating temperature0 - 50°C
Screen diagonal3.5inch
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces USB1
Supporting protocol for LONNo
Voltage type of supply voltageDC
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet1
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces other0
Number of colours of the display65536
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
With colour displayYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUSNo
Number of function buttons, programmable0
With numeric keyboardYes
Number of pixels, vertical240
Number of password levels200
Number of pixels, horizontal320
Process value representation (output) possibleYes
Process default value (input) possibleYes
Useful project memory/user memory64000kByte
With alpha numeric keyboardYes
With recipesYes
With printer outputYes
Number of online languages100
With SW interfacesYes
Additional software components, loadableYes
Width of the front136mm
Degree of protection (IP), front sideIP65
With message indicationYes
With message system (incl. buffer and confirmation)Yes
Height of the front100mm
Rail mounting possibleNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Wall mounting/direct mountingNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard BluetoothNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
IO link masterNo
Radio standard Wi-Fi 802.11No
Type of displayTFT
Supply voltage DC20.4 - 28.8V
Supporting protocol for SafetyBUS pNo
Radio standard GPRSNo
Radio standard UMTSNo
Number of buttons with LED0
Supply voltage AC 50 Hz0 - 0V
Number of grey-scales/blue-scales of display0
Radio standard GSMNo
Supply voltage AC 60 Hz0 - 0V
Degree of protection (NEMA), front side4X
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Touch technologyResistive touch
Number of system buttons1
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group G (non-conductive dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-B0-35TQR-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

25mm

Power consumption

5W

Suitable for safety functions

Operating temperature

0 .. 50°C

Screen diagonal

3.5inch

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

1

Supporting protocol for LON

Voltage type of supply voltage

DC

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

Number of colours of the display

65536

Supporting protocol for TCP/IP

Supporting protocol for KNX

With colour display

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for CAN

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Number of function buttons, programmable

0

With numeric keyboard

Number of pixels, vertical

240

Number of password levels

200

Number of pixels, horizontal

320

Process value representation (output) possible

Process default value (input) possible

Useful project memory/user memory

64000kByte

With alpha numeric keyboard

With recipes

With printer output

Number of online languages

100

With SW interfaces

Additional software components, loadable

Width of the front

136mm

Degree of protection (IP), front side

IP65

With message indication

With message system (incl. buffer and confirmation)

Height of the front

100mm

Rail mounting possible

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Number of HW-interfaces Wireless

0

Wall mounting/direct mounting

Supporting protocol for INTERBUS-Safety

Radio standard Bluetooth

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

IO link master

Radio standard Wi-Fi 802.11

Type of display

TFT

Supply voltage DC

20.4 .. 28.8V

Supporting protocol for SafetyBUS p

Radio standard GPRS

Radio standard UMTS

Number of buttons with LED

0

Supply voltage AC 50 Hz

0 .. 0V

Number of grey-scales/blue-scales of display

0

Radio standard GSM

Supply voltage AC 60 Hz

0 .. 0V

Degree of protection (NEMA), front side

4X

Supporting protocol for EtherCAT

Certified for UL hazardous location class I

Touch technology

Resistive touch

Number of system buttons

1

Certified for UL hazardous location class II

Certified for UL hazardous location division 2

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location division 1

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location class III

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group G (non-conductive dusts)

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.