Technical specifications

Built-in depth25mm
Power consumption5W
Number of HW-interfaces USB1
Supporting protocol for TCP/IPYes
Screen diagonal3.5inch
Operating temperature0 - 50°C
Supporting protocol for CANYes
Suitable for safety functionsNo
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusYes
Voltage type of supply voltageDC
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4850
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
With colour displayYes
With numeric keyboardYes
Number of pixels, horizontal320
Useful project memory/user memory64000kByte
Process value representation (output) possibleYes
With message system (incl. buffer and confirmation)Yes
With alpha numeric keyboardYes
Number of colours of the display65536
With message indicationYes
Number of function buttons, programmable0
Process default value (input) possibleYes
Number of pixels, vertical240
With printer outputYes
Supporting protocol for SERCOSNo
Number of online languages100
With SW interfacesYes
Number of interfaces PROFINET0
Rail mounting possibleNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP), front sideIP65
Width of the front136mm
Number of password levels200
Additional software components, loadableYes
With recipesYes
Height of the front100mm
Radio standard BluetoothNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Radio standard Wi-Fi 802.11No
IO link masterNo
Supporting protocol for SafetyBUS pNo
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
Wall mounting/direct mountingNo
Number of system buttons1
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Type of displayTFT
Number of buttons with LED0
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for DeviceNet SafetyNo
Supply voltage AC 50 Hz0 - 0V
Radio standard UMTSNo
Supply voltage DC20.4 - 28.8V
Number of grey-scales/blue-scales of display0
Radio standard GPRSNo
Supporting protocol for PROFIsafeNo
Radio standard GSMNo
Touch technologyResistive touch
Degree of protection (NEMA), front side4X
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location division 2No
Supporting protocol for EtherCATNo
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group D (propane)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-B5-35TQR-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

25mm

Power consumption

5W

Number of HW-interfaces USB

1

Supporting protocol for TCP/IP

Screen diagonal

3.5inch

Operating temperature

0 .. 50°C

Supporting protocol for CAN

Suitable for safety functions

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Voltage type of supply voltage

DC

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-485

0

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

With colour display

With numeric keyboard

Number of pixels, horizontal

320

Useful project memory/user memory

64000kByte

Process value representation (output) possible

With message system (incl. buffer and confirmation)

With alpha numeric keyboard

Number of colours of the display

65536

With message indication

Number of function buttons, programmable

0

Process default value (input) possible

Number of pixels, vertical

240

With printer output

Supporting protocol for SERCOS

Number of online languages

100

With SW interfaces

Number of interfaces PROFINET

0

Rail mounting possible

Supporting protocol for INTERBUS-Safety

Degree of protection (IP), front side

IP65

Width of the front

136mm

Number of password levels

200

Additional software components, loadable

With recipes

Height of the front

100mm

Radio standard Bluetooth

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Radio standard Wi-Fi 802.11

IO link master

Supporting protocol for SafetyBUS p

Number of HW-interfaces Wireless

0

Supporting protocol for AS-Interface Safety at Work

Wall mounting/direct mounting

Number of system buttons

1

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Type of display

TFT

Number of buttons with LED

0

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for DeviceNet Safety

Supply voltage AC 50 Hz

0 .. 0V

Radio standard UMTS

Supply voltage DC

20.4 .. 28.8V

Number of grey-scales/blue-scales of display

0

Radio standard GPRS

Supporting protocol for PROFIsafe

Radio standard GSM

Touch technology

Resistive touch

Degree of protection (NEMA), front side

4X

Certified for UL hazardous location class II

Certified for UL hazardous location class III

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location class I

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location division 2

Supporting protocol for EtherCAT

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location division 1

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group D (propane)