Technical specifications

Built-in depth25mm
Power consumption5W
Screen diagonal3.5inch
Suitable for safety functionsNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Voltage type of supply voltageDC
Operating temperature0 - 50°C
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB1
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Number of pixels, horizontal320
Number of function buttons, programmable0
Number of pixels, vertical240
With colour displayNo
Number of colours of the display32
With alpha numeric keyboardYes
With message indicationYes
With numeric keyboardYes
Useful project memory/user memory64000kByte
Number of HW-interfaces other1
Number of password levels200
Process default value (input) possibleYes
With recipesYes
Process value representation (output) possibleYes
Additional software components, loadableYes
Number of online languages100
With SW interfacesYes
Width of the front136mm
Degree of protection (IP), front sideIP65
Radio standard Wi-Fi 802.11No
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleNo
Number of HW-interfaces Wireless0
Radio standard BluetoothNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Wall mounting/direct mountingNo
With printer outputYes
Height of the front100mm
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
With message system (incl. buffer and confirmation)Yes
Supporting protocol for DeviceNet SafetyNo
IO link masterNo
Supporting protocol for Foundation FieldbusNo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Type of displayTFT
Supply voltage AC 60 Hz0 - 0V
Number of grey-scales/blue-scales of display32
Number of buttons with LED0
Radio standard GSMNo
Radio standard GPRSNo
Degree of protection (NEMA), front side4X
Radio standard UMTSNo
Touch technologyResistive touch
Number of system buttons1
Certified for UL hazardous location class INo
Supporting protocol for EtherCATNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group C (ethylene)No
Supply voltage DC20.4 - 28.8V
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-B6-35MQR-10-PLC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

25mm

Power consumption

5W

Screen diagonal

3.5inch

Suitable for safety functions

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Voltage type of supply voltage

DC

Operating temperature

0 .. 50°C

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for KNX

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for TCP/IP

Number of HW-interfaces USB

1

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Number of pixels, horizontal

320

Number of function buttons, programmable

0

Number of pixels, vertical

240

With colour display

Number of colours of the display

32

With alpha numeric keyboard

With message indication

With numeric keyboard

Useful project memory/user memory

64000kByte

Number of HW-interfaces other

1

Number of password levels

200

Process default value (input) possible

With recipes

Process value representation (output) possible

Additional software components, loadable

Number of online languages

100

With SW interfaces

Width of the front

136mm

Degree of protection (IP), front side

IP65

Radio standard Wi-Fi 802.11

Supporting protocol for INTERBUS-Safety

Rail mounting possible

Number of HW-interfaces Wireless

0

Radio standard Bluetooth

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Wall mounting/direct mounting

With printer output

Height of the front

100mm

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

With message system (incl. buffer and confirmation)

Supporting protocol for DeviceNet Safety

IO link master

Supporting protocol for Foundation Fieldbus

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Type of display

TFT

Supply voltage AC 60 Hz

0 .. 0V

Number of grey-scales/blue-scales of display

32

Number of buttons with LED

0

Radio standard GSM

Radio standard GPRS

Degree of protection (NEMA), front side

4X

Radio standard UMTS

Touch technology

Resistive touch

Number of system buttons

1

Certified for UL hazardous location class I

Supporting protocol for EtherCAT

Certified for UL hazardous location division 1

Certified for UL hazardous location division 2

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location class II

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location class III

Certified for UL hazardous location group C (ethylene)

Supply voltage DC

20.4 .. 28.8V

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)