Aleta.hr

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functionsNo
Screen diagonal5.7inch
Power consumption9.5W
Operating temperature0 - 50°C
Built-in depth34mm
Voltage type of supply voltageDC
Supporting protocol for LONNo
Number of pixels, horizontal640
Number of HW-interfaces RS-2321
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
With colour displayYes
Number of HW-interfaces serial TTY0
Number of colours of the display65536
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB2
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4851
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Number of HW-interfaces RS-4220
With numeric keyboardYes
Supporting protocol for INTERBUSNo
Number of function buttons, programmable0
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
Number of pixels, vertical480
Supporting protocol for KNXNo
Process value representation (output) possibleYes
With recipesYes
Number of password levels200
Number of online languages100
With SW interfacesYes
Useful project memory/user memory64000kByte
Rail mounting possibleNo
Height of the front130mm
Additional software components, loadableYes
Degree of protection (IP), front sideIP65
Process default value (input) possibleYes
With message indicationYes
Width of the front170mm
With message system (incl. buffer and confirmation)Yes
With printer outputYes
With alpha numeric keyboardYes
Number of interfaces PROFINET0
Radio standard Wi-Fi 802.11No
IO link masterNo
Number of HW-interfaces Wireless0
Radio standard BluetoothNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Wall mounting/direct mountingNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Type of displayTFT
Supply voltage DC20.4 - 28.8V
Number of system buttons1
Radio standard GPRSNo
Certified for UL hazardous location class INo
Supporting protocol for EtherCATNo
Radio standard UMTSNo
Number of buttons with LED0
Number of grey-scales/blue-scales of display0
Degree of protection (NEMA), front side4X
Certified for UL hazardous location class IINo
Touch technologyResistive touch
Radio standard GSMNo
Certified for UL hazardous location division 2No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-D6-57TVR-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functions

Screen diagonal

5.7inch

Power consumption

9.5W

Operating temperature

0 .. 50°C

Built-in depth

34mm

Voltage type of supply voltage

DC

Supporting protocol for LON

Number of pixels, horizontal

640

Number of HW-interfaces RS-232

1

Supporting protocol for ASI

Supporting protocol for TCP/IP

With colour display

Number of HW-interfaces serial TTY

0

Number of colours of the display

65536

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

2

Supporting protocol for SUCONET

Number of HW-interfaces RS-485

1

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Number of HW-interfaces RS-422

0

With numeric keyboard

Supporting protocol for INTERBUS

Number of function buttons, programmable

0

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for other bus systems

Number of pixels, vertical

480

Supporting protocol for KNX

Process value representation (output) possible

With recipes

Number of password levels

200

Number of online languages

100

With SW interfaces

Useful project memory/user memory

64000kByte

Rail mounting possible

Height of the front

130mm

Additional software components, loadable

Degree of protection (IP), front side

IP65

Process default value (input) possible

With message indication

Width of the front

170mm

With message system (incl. buffer and confirmation)

With printer output

With alpha numeric keyboard

Number of interfaces PROFINET

0

Radio standard Wi-Fi 802.11

IO link master

Number of HW-interfaces Wireless

0

Radio standard Bluetooth

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Wall mounting/direct mounting

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Type of display

TFT

Supply voltage DC

20.4 .. 28.8V

Number of system buttons

1

Radio standard GPRS

Certified for UL hazardous location class I

Supporting protocol for EtherCAT

Radio standard UMTS

Number of buttons with LED

0

Number of grey-scales/blue-scales of display

0

Degree of protection (NEMA), front side

4X

Certified for UL hazardous location class II

Touch technology

Resistive touch

Radio standard GSM

Certified for UL hazardous location division 2

Certified for UL hazardous location class III

Certified for UL hazardous location division 1

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)

Related products