Aleta.hr

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Power consumption10W
Suitable for safety functionsNo
Built-in depth33mm
Screen diagonal7inch
Number of HW-interfaces industrial Ethernet1
Supporting protocol for LONNo
Operating temperature0 - 50°C
Voltage type of supply voltageDC
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for other bus systemsYes
Number of HW-interfaces RS-2321
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB2
Supporting protocol for CANYes
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Number of colours of the display65536
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
With colour displayYes
With alpha numeric keyboardYes
Number of pixels, vertical480
Number of function buttons, programmable0
Number of pixels, horizontal800
With numeric keyboardYes
With recipesYes
Number of password levels200
Additional software components, loadableYes
With message system (incl. buffer and confirmation)Yes
Useful project memory/user memory64000kByte
With message indicationYes
With printer outputYes
Process default value (input) possibleYes
Number of online languages100
Process value representation (output) possibleYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Degree of protection (IP), front sideIP65
Height of the front135mm
Radio standard BluetoothNo
With SW interfacesYes
Number of HW-interfaces Wireless0
Rail mounting possibleNo
Supporting protocol for SERCOSNo
Width of the front210mm
Radio standard Wi-Fi 802.11No
Supporting protocol for AS-Interface Safety at WorkNo
Wall mounting/direct mountingNo
IO link masterNo
Supporting protocol for Foundation FieldbusNo
Number of buttons with LED0
Certified for UL hazardous location class IINo
Number of grey-scales/blue-scales of display0
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supply voltage AC 50 Hz0 - 0V
Type of displayTFT
Radio standard GPRSNo
Touch technologyResistive touch
Supply voltage DC20.4 - 28.8V
Degree of protection (NEMA), front side4X
Radio standard GSMNo
Certified for UL hazardous location class INo
Supporting protocol for PROFINET CBANo
Supply voltage AC 60 Hz0 - 0V
Number of system buttons1
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Supporting protocol for EtherCATNo
Radio standard UMTSNo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-D6-70TWR-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Power consumption

10W

Suitable for safety functions

Built-in depth

33mm

Screen diagonal

7inch

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for LON

Operating temperature

0 .. 50°C

Voltage type of supply voltage

DC

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for other bus systems

Number of HW-interfaces RS-232

1

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

2

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Number of colours of the display

65536

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for PROFIBUS

With colour display

With alpha numeric keyboard

Number of pixels, vertical

480

Number of function buttons, programmable

0

Number of pixels, horizontal

800

With numeric keyboard

With recipes

Number of password levels

200

Additional software components, loadable

With message system (incl. buffer and confirmation)

Useful project memory/user memory

64000kByte

With message indication

With printer output

Process default value (input) possible

Number of online languages

100

Process value representation (output) possible

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Degree of protection (IP), front side

IP65

Height of the front

135mm

Radio standard Bluetooth

With SW interfaces

Number of HW-interfaces Wireless

0

Rail mounting possible

Supporting protocol for SERCOS

Width of the front

210mm

Radio standard Wi-Fi 802.11

Supporting protocol for AS-Interface Safety at Work

Wall mounting/direct mounting

IO link master

Supporting protocol for Foundation Fieldbus

Number of buttons with LED

0

Certified for UL hazardous location class II

Number of grey-scales/blue-scales of display

0

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supply voltage AC 50 Hz

0 .. 0V

Type of display

TFT

Radio standard GPRS

Touch technology

Resistive touch

Supply voltage DC

20.4 .. 28.8V

Degree of protection (NEMA), front side

4X

Radio standard GSM

Certified for UL hazardous location class I

Supporting protocol for PROFINET CBA

Supply voltage AC 60 Hz

0 .. 0V

Number of system buttons

1

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for EtherCAT

Radio standard UMTS

Certified for UL hazardous location class III

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location division 1

Certified for UL hazardous location division 2

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)