  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet1
Supporting protocol for LONNo
Built-in depth25mm
Operating temperature0 - 50°C
Suitable for safety functionsNo
Power consumption5W
Screen diagonal3.5inch
Voltage type of supply voltageDC
Number of HW-interfaces RS-2321
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces USB1
Number of HW-interfaces parallel0
With colour displayYes
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4850
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Useful project memory/user memory64000kByte
With numeric keyboardYes
Number of pixels, horizontal320
Number of function buttons, programmable0
Number of pixels, vertical240
With alpha numeric keyboardYes
Number of colours of the display65536
With printer outputYes
Process value representation (output) possibleYes
With message indicationYes
Degree of protection (IP), front sideIP65
With message system (incl. buffer and confirmation)Yes
Number of password levels200
Process default value (input) possibleYes
Additional software components, loadableYes
Number of online languages100
With recipesYes
Supporting protocol for SERCOSNo
Height of the front100mm
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleNo
With SW interfacesYes
Wall mounting/direct mountingNo
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Width of the front136mm
IO link masterNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Radio standard BluetoothNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard Wi-Fi 802.11No
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Radio standard GSMNo
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC20.4 - 28.8V
Supporting protocol for PROFINET IONo
Number of grey-scales/blue-scales of display0
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IIINo
Touch technologyResistive touch
Certified for UL hazardous location class INo
Number of buttons with LED0
Radio standard UMTSNo
Degree of protection (NEMA), front side4X
Type of displayTFT
Radio standard GPRSNo
Supporting protocol for EtherCATNo
Number of system buttons1
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 2No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-102-H3-35TQRL-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for LON

Built-in depth

25mm

Operating temperature

0 .. 50°C

Suitable for safety functions

Power consumption

5W

Screen diagonal

3.5inch

Voltage type of supply voltage

DC

Number of HW-interfaces RS-232

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Number of HW-interfaces USB

1

Number of HW-interfaces parallel

0

With colour display

Supporting protocol for SUCONET

Number of HW-interfaces RS-485

0

Supporting protocol for ASI

Supporting protocol for other bus systems

Supporting protocol for Modbus

Useful project memory/user memory

64000kByte

With numeric keyboard

Number of pixels, horizontal

320

Number of function buttons, programmable

0

Number of pixels, vertical

240

With alpha numeric keyboard

Number of colours of the display

65536

With printer output

Process value representation (output) possible

With message indication

Degree of protection (IP), front side

IP65

With message system (incl. buffer and confirmation)

Number of password levels

200

Process default value (input) possible

Additional software components, loadable

Number of online languages

100

With recipes

Supporting protocol for SERCOS

Height of the front

100mm

Supporting protocol for INTERBUS-Safety

Rail mounting possible

With SW interfaces

Wall mounting/direct mounting

Number of interfaces PROFINET

0

Number of HW-interfaces Wireless

0

Width of the front

136mm

IO link master

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Radio standard Bluetooth

Supporting protocol for AS-Interface Safety at Work

Radio standard Wi-Fi 802.11

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Radio standard GSM

Supply voltage AC 60 Hz

0 .. 0V

Supply voltage DC

20.4 .. 28.8V

Supporting protocol for PROFINET IO

Number of grey-scales/blue-scales of display

0

Certified for UL hazardous location division 1

Certified for UL hazardous location class III

Touch technology

Resistive touch

Certified for UL hazardous location class I

Number of buttons with LED

0

Radio standard UMTS

Degree of protection (NEMA), front side

4X

Type of display

TFT

Radio standard GPRS

Supporting protocol for EtherCAT

Number of system buttons

1

Certified for UL hazardous location class II

Certified for UL hazardous location division 2

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)