Aleta.hr

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth47mm
Power consumption9.5W
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2321
Number of HW-interfaces USB2
Voltage type of supply voltageDC
Number of HW-interfaces RS-4220
Operating temperature0 - 50°C
Number of HW-interfaces industrial Ethernet1
Suitable for safety functionsNo
Number of HW-interfaces RS-4850
Screen diagonal8.4inch
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
Number of colours of the display65536
Process default value (input) possibleYes
With colour displayYes
Number of pixels, vertical480
With message system (incl. buffer and confirmation)Yes
Supporting protocol for Data-HighwayNo
Useful project memory/user memory64000kByte
With alpha numeric keyboardYes
With recipesYes
Number of pixels, horizontal640
With numeric keyboardYes
With message indicationYes
Process value representation (output) possibleYes
Number of function buttons, programmable0
Supporting protocol for DeviceNetNo
Number of password levels200
Degree of protection (IP), front sideIP65
Number of online languages100
With printer outputYes
With SW interfacesYes
Rail mounting possibleNo
Height of the front208mm
Width of the front275mm
Additional software components, loadableYes
IO link masterNo
Supporting protocol for Foundation FieldbusNo
Wall mounting/direct mountingNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Number of HW-interfaces Wireless0
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Radio standard BluetoothNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Certified for UL hazardous location division 1No
Touch technologyResistive touch
Certified for UL hazardous location group D (propane)No
Radio standard GSMNo
Certified for UL hazardous location group A (acetylene)No
Supply voltage AC 60 Hz0 - 0V
Number of system buttons1
Certified for UL hazardous location class IIINo
Supply voltage DC20.4 - 28.8V
Certified for UL hazardous location class IINo
Radio standard UMTSNo
Degree of protection (NEMA), front side4X
Certified for UL hazardous location group F (carbonaceous dusts)No
Number of grey-scales/blue-scales of display0
Certified for UL hazardous location group B (hydrogen)No
Supply voltage AC 50 Hz0 - 0V
Certified for UL hazardous location class INo
Supporting protocol for EtherCATNo
Certified for UL hazardous location division 2No
Radio standard GPRSNo
Number of buttons with LED0
Certified for UL hazardous location group C (ethylene)No
Type of displayTFT
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-152-D0-84TVR-10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

47mm

Power consumption

9.5W

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces USB

2

Voltage type of supply voltage

DC

Number of HW-interfaces RS-422

0

Operating temperature

0 .. 50°C

Number of HW-interfaces industrial Ethernet

1

Suitable for safety functions

Number of HW-interfaces RS-485

0

Screen diagonal

8.4inch

Supporting protocol for LON

Supporting protocol for INTERBUS

Number of HW-interfaces other

0

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for Modbus

Number of colours of the display

65536

Process default value (input) possible

With colour display

Number of pixels, vertical

480

With message system (incl. buffer and confirmation)

Supporting protocol for Data-Highway

Useful project memory/user memory

64000kByte

With alpha numeric keyboard

With recipes

Number of pixels, horizontal

640

With numeric keyboard

With message indication

Process value representation (output) possible

Number of function buttons, programmable

0

Supporting protocol for DeviceNet

Number of password levels

200

Degree of protection (IP), front side

IP65

Number of online languages

100

With printer output

With SW interfaces

Rail mounting possible

Height of the front

208mm

Width of the front

275mm

Additional software components, loadable

IO link master

Supporting protocol for Foundation Fieldbus

Wall mounting/direct mounting

Radio standard Wi-Fi 802.11

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Number of HW-interfaces Wireless

0

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Radio standard Bluetooth

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Certified for UL hazardous location division 1

Touch technology

Resistive touch

Certified for UL hazardous location group D (propane)

Radio standard GSM

Certified for UL hazardous location group A (acetylene)

Supply voltage AC 60 Hz

0 .. 0V

Number of system buttons

1

Certified for UL hazardous location class III

Supply voltage DC

20.4 .. 28.8V

Certified for UL hazardous location class II

Radio standard UMTS

Degree of protection (NEMA), front side

4X

Certified for UL hazardous location group F (carbonaceous dusts)

Number of grey-scales/blue-scales of display

0

Certified for UL hazardous location group B (hydrogen)

Supply voltage AC 50 Hz

0 .. 0V

Certified for UL hazardous location class I

Supporting protocol for EtherCAT

Certified for UL hazardous location division 2

Radio standard GPRS

Number of buttons with LED

0

Certified for UL hazardous location group C (ethylene)

Type of display

TFT

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group G (non-conductive dusts)

Related products