Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-2321
Supporting protocol for LONNo
Suitable for safety functionsNo
Supporting protocol for CANYes
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Number of HW-interfaces other2
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Operating temperature0 - 50°C
Number of HW-interfaces USB2
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Number of colours of the display16777216
Supporting protocol for other bus systemsYes
Number of pixels, horizontal1024
Number of pixels, vertical600
Useful project memory/user memory512000kByte
Number of function buttons, programmable0
With alpha numeric keyboardNo
Number of online languages100
With message system (incl. buffer and confirmation)Yes
Supporting protocol for INTERBUS-SafetyNo
Number of password levels200
Process default value (input) possibleYes
Supporting protocol for SERCOSNo
Additional software components, loadableYes
Process value representation (output) possibleYes
With message indicationYes
Number of HW-interfaces Wireless0
Wall mounting/direct mountingNo
Supporting protocol for Foundation FieldbusNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Number of interfaces PROFINET0
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Number of grey-scales/blue-scales of display0
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Radio standard BluetoothNo
Supporting protocol for EtherNet/IPYes
Touch technologyCapacitive multitouch
Number of buttons with LED0
Number of system buttons1
Degree of protection (NEMA), front side12
Certified for UL hazardous location class INo
Supporting protocol for EtherCATYes
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Voltage type of supply voltageDC
Degree of protection (IP), front sideIP65
Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC19.2 - 30V