Suitable for safety functionsNo
Power consumption14.4W
Voltage type of supply voltageDC
Built-in depth43.1mm
Screen diagonal7inch
Operating temperature0 - 50°C
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB2
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSNo
Number of HW-interfaces parallel0
Supporting protocol for CANYes
Number of HW-interfaces other1
Number of HW-interfaces RS-2321
Supporting protocol for ASINo
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Number of pixels, horizontal1024
Number of colours of the display16777216
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
With colour displayYes
Supporting protocol for other bus systemsNo
Number of pixels, vertical600
Number of function buttons, programmable0
With numeric keyboardNo
Useful project memory/user memory512000kByte
Number of password levels200
With alpha numeric keyboardNo
With message indicationYes
Additional software components, loadableYes
With message system (incl. buffer and confirmation)Yes
With SW interfacesYes
Degree of protection (IP), front sideIP65
Number of online languages100
Width of the front196mm
With printer outputYes
Process default value (input) possibleYes
Number of interfaces PROFINET0
With recipesYes
Supporting protocol for SERCOSNo
Radio standard Wi-Fi 802.11No
Process value representation (output) possibleYes
Radio standard BluetoothNo
Rail mounting possibleNo
Wall mounting/direct mountingNo
Supporting protocol for INTERBUS-SafetyNo
Height of the front135mm
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
IO link masterNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Type of displayTFT
Supporting protocol for EtherNet/IPYes
Supply voltage DC19.2 - 30V
Number of grey-scales/blue-scales of display0
Degree of protection (NEMA), front side12
Certified for UL hazardous location division 2No
Certified for UL hazardous location class INo
Certified for UL hazardous location division 1No
Supporting protocol for PROFIsafeNo
Touch technologyCapacitive multitouch
Supporting protocol for PROFINET IONo
Certified for UL hazardous location class IIINo
Supply voltage AC 60 Hz0 - 0V
Radio standard GSMNo
Number of system buttons1
Radio standard UMTSNo
Supporting protocol for EtherCATYes
Supply voltage AC 50 Hz0 - 0V
Certified for UL hazardous location class IINo
Number of buttons with LED0
Supporting protocol for PROFINET CBANo
Radio standard GPRSNo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XV-303-70-B00-A00-1B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Graphic panel
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functions

Power consumption

14.4W

Voltage type of supply voltage

DC

Built-in depth

43.1mm

Screen diagonal

7inch

Operating temperature

0 .. 50°C

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

2

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Number of HW-interfaces other

1

Number of HW-interfaces RS-232

1

Supporting protocol for ASI

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Number of pixels, horizontal

1024

Number of colours of the display

16777216

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for SUCONET

With colour display

Supporting protocol for other bus systems

Number of pixels, vertical

600

Number of function buttons, programmable

0

With numeric keyboard

Useful project memory/user memory

512000kByte

Number of password levels

200

With alpha numeric keyboard

With message indication

Additional software components, loadable

With message system (incl. buffer and confirmation)

With SW interfaces

Degree of protection (IP), front side

IP65

Number of online languages

100

Width of the front

196mm

With printer output

Process default value (input) possible

Number of interfaces PROFINET

0

With recipes

Supporting protocol for SERCOS

Radio standard Wi-Fi 802.11

Process value representation (output) possible

Radio standard Bluetooth

Rail mounting possible

Wall mounting/direct mounting

Supporting protocol for INTERBUS-Safety

Height of the front

135mm

Number of HW-interfaces Wireless

0

Supporting protocol for AS-Interface Safety at Work

IO link master

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Type of display

TFT

Supporting protocol for EtherNet/IP

Supply voltage DC

19.2 .. 30V

Number of grey-scales/blue-scales of display

0

Degree of protection (NEMA), front side

12

Certified for UL hazardous location division 2

Certified for UL hazardous location class I

Certified for UL hazardous location division 1

Supporting protocol for PROFIsafe

Touch technology

Capacitive multitouch

Supporting protocol for PROFINET IO

Certified for UL hazardous location class III

Supply voltage AC 60 Hz

0 .. 0V

Radio standard GSM

Number of system buttons

1

Radio standard UMTS

Supporting protocol for EtherCAT

Supply voltage AC 50 Hz

0 .. 0V

Certified for UL hazardous location class II

Number of buttons with LED

0

Supporting protocol for PROFINET CBA

Radio standard GPRS

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group G (non-conductive dusts)

Related products