Technical specifications

Rated voltage-V
Built-in depth69mm
Rated current20A
Release characteristicC
Frequency50 - 60Hz
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings-
Power loss-W
Current limiting class3
Over voltage category-
Pollution degree2
Rated insulation voltage Ui-V
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of protected poles1
Number of poles (total)1
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251025R0204 | SZ201-C20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Built-in depth

69mm

Rated current

20A

Release characteristic

C

Frequency

50 .. 60Hz

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

-

Power loss

-W

Current limiting class

3

Over voltage category

-

Pollution degree

2

Rated insulation voltage Ui

-V

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Number of poles (total)

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV