Voltage typeAC/DC
Flush-mounted installationNo
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Power loss-W
Connectable conductor cross section multi-wired0 - 35mm²
Rated current63A
Over voltage category3
Degree of protection (IP)IP2X
Number of protected poles1
Release characteristicB
Width in number of modular spacings1
Current limiting class3
Number of poles (total)1
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 25mm²
Frequency50 - 60Hz
Explosion-proofNo
Concurrently switching neutral conductorNo
Pollution degree3
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251025R0635 | SZ201-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Flush-mounted installation

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Power loss

-W

Connectable conductor cross section multi-wired

0 .. 35mm²

Rated current

63A

Over voltage category

3

Degree of protection (IP)

IP2X

Number of protected poles

1

Release characteristic

B

Width in number of modular spacings

1

Current limiting class

3

Number of poles (total)

1

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 25mm²

Frequency

50 .. 60Hz

Explosion-proof

Concurrently switching neutral conductor

Pollution degree

3

Suitable for flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV