Aleta.hr
Main Product Image

2CDS253025R0165 | SZ203-B16

Code: 1885801

ManufacturerABB
Catalog number2CDS253025R0165
EAN code4016779996686

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Release characteristicB
Rated current16A
Built-in depth69mm
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss-W
Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Number of protected poles3
Pollution degree2
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings3.0
Flush-mounted installationNo
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253025R0165 | SZ203-B16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

B

Rated current

16A

Built-in depth

69mm

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

-W

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Number of protected poles

3

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

3.0

Flush-mounted installation

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

From same serie

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.