Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Degree of protection (IP)IP20
Width in number of modular spacings3.0
Pollution degree2
Explosion-proofNo
Power loss-W
Rated current63A
Frequency50 - 60Hz
Over voltage category3
Release characteristicC
Rated voltage400V
Built-in depth69mm
Voltage typeOther
Rated insulation voltage Ui440V
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core0.75 - 35mm²
Number of poles (total)3
Flush-mounted installationNo

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253025R0634 | SZ203-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3.0

Pollution degree

2

Explosion-proof

Power loss

-W

Rated current

63A

Frequency

50 .. 60Hz

Over voltage category

3

Release characteristic

C

Rated voltage

400V

Built-in depth

69mm

Voltage type

Other

Rated insulation voltage Ui

440V

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of poles (total)

3

Flush-mounted installation

From same serie

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.