Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated voltage230V
Current limiting class-
Leakage current typeAC
Release characteristicC
Rated fault current0.03A
Voltage typeAC
Pollution degree2
Rated insulation voltage Ui-V
Rated current6A
Surge current capacity0kA
Over voltage category3
Suitable for flush-mounted installationNo
Degree of protection (IP)IP2X
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wiredmm²
Width in number of modular spacings2
Number of protected poles1
Connectable conductor cross section solid-coremm²
With interlocking deviceNo
Number of poles (total)2
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255080R1064 | DS201 C6 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

230V

Current limiting class

-

Leakage current type

AC

Release characteristic

C

Rated fault current

0.03A

Voltage type

AC

Pollution degree

2

Rated insulation voltage Ui

-V

Rated current

6A

Surge current capacity

0kA

Over voltage category

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

mm²

Width in number of modular spacings

2

Number of protected poles

1

Connectable conductor cross section solid-core

mm²

With interlocking device

Number of poles (total)

2

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

From same serie