Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated current6A
Leakage current typeAC
Rated voltage230V
Rated insulation voltage Ui-V
Surge current capacity0kA
Built-in depth69mm
Release characteristicB
Rated fault current0.03A
Pollution degree2
Frequency50/60 Hz
Width in number of modular spacings2
Over voltage category3
Degree of protection (IP)IP2X
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section multi-wiredmm²
Concurrently switching neutral conductorYes
Current limiting class-
With interlocking deviceNo
Connectable conductor cross section solid-coremm²
Number of protected poles1
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255080R1065 | DS201 B6 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

6A

Leakage current type

AC

Rated voltage

230V

Rated insulation voltage Ui

-V

Surge current capacity

0kA

Built-in depth

69mm

Release characteristic

B

Rated fault current

0.03A

Pollution degree

2

Frequency

50/60 Hz

Width in number of modular spacings

2

Over voltage category

3

Degree of protection (IP)

IP2X

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section multi-wired

mm²

Concurrently switching neutral conductor

Current limiting class

-

With interlocking device

Connectable conductor cross section solid-core

mm²

Number of protected poles

1

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2