Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Surge current capacity0kA
Rated voltage230V
Rated current10A
Rated fault current0.1A
Leakage current typeAC
Rated insulation voltage Ui-V
Release characteristicB
Built-in depth69mm
Number of protected poles1
Current limiting class-
Power loss2.3W
Number of poles (total)2
Flush-mounted installationNo
Frequency50/60 Hz
Pollution degree2
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-coremm²
Connectable conductor cross section multi-wiredmm²
Degree of protection (IP)IP2X
Width in number of modular spacings2
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255080R2105 | DS201 B10 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Surge current capacity

0kA

Rated voltage

230V

Rated current

10A

Rated fault current

0.1A

Leakage current type

AC

Rated insulation voltage Ui

-V

Release characteristic

B

Built-in depth

69mm

Number of protected poles

1

Current limiting class

-

Power loss

2.3W

Number of poles (total)

2

Flush-mounted installation

Frequency

50/60 Hz

Pollution degree

2

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

mm²

Connectable conductor cross section multi-wired

mm²

Degree of protection (IP)

IP2X

Width in number of modular spacings

2

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.