Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui-V
Built-in depth69mm
Over voltage category3
Voltage typeAC
Current limiting class-
Rated current6A
Rated fault current0.3A
Surge current capacity0kA
Release characteristicB
Pollution degree2
Rated voltage230V
Leakage current typeAC
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Connectable conductor cross section solid-coremm²
Rated short-circuit breaking capacity according to EN 610096kA
Suitable for flush-mounted installationNo
Degree of protection (IP)IP2X
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp-kV
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Frequency50/60 Hz
Connectable conductor cross section multi-wiredmm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255080R3065 | DS201 B6 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

-V

Built-in depth

69mm

Over voltage category

3

Voltage type

AC

Current limiting class

-

Rated current

6A

Rated fault current

0.3A

Surge current capacity

0kA

Release characteristic

B

Pollution degree

2

Rated voltage

230V

Leakage current type

AC

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Connectable conductor cross section solid-core

mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP2X

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

-kV

Width in number of modular spacings

2

Anti-nuisance tripping version

Frequency

50/60 Hz

Connectable conductor cross section multi-wired

mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

With interlocking device

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.