Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current typeAC
Voltage typeAC
Release characteristicC
Surge current capacity0kA
Current limiting class-
Built-in depth69mm
Over voltage category3
Rated current40A
Rated insulation voltage Ui-V
Rated fault current0.3A
Rated voltage230V
Pollution degree2
Width in number of modular spacings2
Frequency50/60 Hz
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-coremm²
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section multi-wiredmm²
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Number of protected poles1
With interlocking deviceNo
Rated impulse withstand voltage Uimp-kV
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255080R3404 | DS201 C40 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current type

AC

Voltage type

AC

Release characteristic

C

Surge current capacity

0kA

Current limiting class

-

Built-in depth

69mm

Over voltage category

3

Rated current

40A

Rated insulation voltage Ui

-V

Rated fault current

0.3A

Rated voltage

230V

Pollution degree

2

Width in number of modular spacings

2

Frequency

50/60 Hz

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

mm²

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Number of protected poles

1

With interlocking device

Rated impulse withstand voltage Uimp

-kV

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.