Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth69mm
Leakage current typeA
Current limiting class-
Pollution degree2
Frequency50/60 Hz
Surge current capacity-kA
Degree of protection (IP)IP2X
Connectable conductor cross section multi-wiredmm²
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Release characteristicB
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-coremm²
Rated insulation voltage Ui-V
Over voltage category3
Rated impulse withstand voltage Uimp-kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)2
Number of protected poles1
Rated voltage230V
Rated current16A
Rated fault current0.03A
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R1165 | DS201 B16 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

69mm

Leakage current type

A

Current limiting class

-

Pollution degree

2

Frequency

50/60 Hz

Surge current capacity

-kA

Degree of protection (IP)

IP2X

Connectable conductor cross section multi-wired

mm²

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

2

Suitable for flush-mounted installation

Release characteristic

B

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

mm²

Rated insulation voltage Ui

-V

Over voltage category

3

Rated impulse withstand voltage Uimp

-kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

2

Number of protected poles

1

Rated voltage

230V

Rated current

16A

Rated fault current

0.03A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.