Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Release characteristicK
Voltage typeAC
Rated current16A
Built-in depth69mm
Frequency50/60 Hz
Width in number of modular spacings2
Rated insulation voltage Ui-V
Leakage current typeA
Current limiting class-
Surge current capacity-kA
Rated fault current0.03A
Pollution degree2
Over voltage category3
Degree of protection (IP)IP2X
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Connectable conductor cross section multi-wiredmm²
Number of protected poles1
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-coremm²
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R1167 | DS201 K16 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Release characteristic

K

Voltage type

AC

Rated current

16A

Built-in depth

69mm

Frequency

50/60 Hz

Width in number of modular spacings

2

Rated insulation voltage Ui

-V

Leakage current type

A

Current limiting class

-

Surge current capacity

-kA

Rated fault current

0.03A

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP2X

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Connectable conductor cross section multi-wired

mm²

Number of protected poles

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

mm²

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.