Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated fault current0.03A
Frequency50/60 Hz
Rated current40A
Width in number of modular spacings2
Number of protected poles1
Surge current capacity-kA
Leakage current typeA
Current limiting class-
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Release characteristicC
Pollution degree2
Rated voltage230V
Over voltage category3
Built-in depth69mm
Rated insulation voltage Ui-V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Connectable conductor cross section solid-coremm²
With interlocking deviceNo
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wiredmm²
Rated short-circuit breaking capacity according to EN 610096kA
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp-kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R1404 | DS201 C40 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated fault current

0.03A

Frequency

50/60 Hz

Rated current

40A

Width in number of modular spacings

2

Number of protected poles

1

Surge current capacity

-kA

Leakage current type

A

Current limiting class

-

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Release characteristic

C

Pollution degree

2

Rated voltage

230V

Over voltage category

3

Built-in depth

69mm

Rated insulation voltage Ui

-V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Connectable conductor cross section solid-core

mm²

With interlocking device

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

-kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.