Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated current20A
Surge current capacity-kA
Number of protected poles1
Release characteristicC
Power loss5.7W
Over voltage category3
Frequency50/60 Hz
Rated insulation voltage Ui-V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Voltage typeAC
Suitable for flush-mounted installationNo
Rated voltage230V
Degree of protection (IP)IP2X
Rated fault current0.1A
Connectable conductor cross section solid-coremm²
Width in number of modular spacings2
Leakage current typeA
Concurrently switching neutral conductorYes
Pollution degree2
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wiredmm²
With interlocking deviceNo
Current limiting class-
Anti-nuisance tripping versionNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R2204 | DS201 C20 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

20A

Surge current capacity

-kA

Number of protected poles

1

Release characteristic

C

Power loss

5.7W

Over voltage category

3

Frequency

50/60 Hz

Rated insulation voltage Ui

-V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Voltage type

AC

Suitable for flush-mounted installation

Rated voltage

230V

Degree of protection (IP)

IP2X

Rated fault current

0.1A

Connectable conductor cross section solid-core

mm²

Width in number of modular spacings

2

Leakage current type

A

Concurrently switching neutral conductor

Pollution degree

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

mm²

With interlocking device

Current limiting class

-

Anti-nuisance tripping version

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.