Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth69mm
Rated voltage230V
Rated current25A
Rated insulation voltage Ui-V
Leakage current typeA
Release characteristicB
Rated fault current0.1A
Current limiting class-
Pollution degree2
Surge current capacity-kA
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wiredmm²
Concurrently switching neutral conductorYes
Flush-mounted installationNo
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Number of poles (total)2
Number of protected poles1
Degree of protection (IP)IP2X
Frequency50/60 Hz
Rated impulse withstand voltage Uimp-kV
Connectable conductor cross section solid-coremm²
Over voltage category3
Power loss8.1W
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R2255 | DS201 B25 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

69mm

Rated voltage

230V

Rated current

25A

Rated insulation voltage Ui

-V

Leakage current type

A

Release characteristic

B

Rated fault current

0.1A

Current limiting class

-

Pollution degree

2

Surge current capacity

-kA

Width in number of modular spacings

2

Suitable for flush-mounted installation

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

mm²

Concurrently switching neutral conductor

Flush-mounted installation

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Number of poles (total)

2

Number of protected poles

1

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Rated impulse withstand voltage Uimp

-kV

Connectable conductor cross section solid-core

mm²

Over voltage category

3

Power loss

8.1W

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.