Aleta.hr
Main Product Image

2CSR255180R3137 | DS201 K13 A300

Code: 1887087

ManufacturerABB
Catalog number2CSR255180R3137
EAN code8012542574910

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wiredmm²
Connectable conductor cross section solid-coremm²
Rated impulse withstand voltage Uimp-kV
Rated insulation voltage Ui-V
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Surge current capacity-kA
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
Number of protected poles1
Rated current13A
Release characteristicK
Suitable for flush-mounted installationNo
Leakage current typeA
With interlocking deviceNo
Rated fault current0.3A
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
Frequency50/60 Hz
Rated voltage230V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Over voltage category3
Built-in depth69mm
Concurrently switching neutral conductorYes
Voltage typeAC
Width in number of modular spacings2
Degree of protection (IP)IP2X
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R3137 | DS201 K13 A300

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wired

mm²

Connectable conductor cross section solid-core

mm²

Rated impulse withstand voltage Uimp

-kV

Rated insulation voltage Ui

-V

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Surge current capacity

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of protected poles

1

Rated current

13A

Release characteristic

K

Suitable for flush-mounted installation

Leakage current type

A

With interlocking device

Rated fault current

0.3A

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

Frequency

50/60 Hz

Rated voltage

230V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Over voltage category

3

Built-in depth

69mm

Concurrently switching neutral conductor

Voltage type

AC

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

Pollution degree

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.