Aleta.hr
Main Product Image

2CSR255180R3165 | DS201 B16 A300

Code: 1887089

ManufacturerABB
Catalog number2CSR255180R3165
EAN code8012542643517

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wiredmm²
Connectable conductor cross section solid-coremm²
Rated impulse withstand voltage Uimp-kV
Rated insulation voltage Ui-V
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Surge current capacity-kA
Number of poles (total)2
Number of protected poles1
Rated fault current0.3A
Leakage current typeA
Rated current16A
Rated short-circuit breaking capacity according to EN 610096kA
Release characteristicB
Rated short-circuit breaking capacity according to IEC 60947-210kA
Frequency50/60 Hz
Rated voltage230V
Concurrently switching neutral conductorYes
Built-in depth69mm
Over voltage category3
Voltage typeAC
Pollution degree2
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Degree of protection (IP)IP2X
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R3165 | DS201 B16 A300

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wired

mm²

Connectable conductor cross section solid-core

mm²

Rated impulse withstand voltage Uimp

-kV

Rated insulation voltage Ui

-V

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Surge current capacity

-kA

Number of poles (total)

2

Number of protected poles

1

Rated fault current

0.3A

Leakage current type

A

Rated current

16A

Rated short-circuit breaking capacity according to EN 61009

6kA

Release characteristic

B

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Frequency

50/60 Hz

Rated voltage

230V

Concurrently switching neutral conductor

Built-in depth

69mm

Over voltage category

3

Voltage type

AC

Pollution degree

2

Suitable for flush-mounted installation

Anti-nuisance tripping version

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Degree of protection (IP)

IP2X

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.