Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui-V
Rated current25A
Rated voltage230V
Built-in depth69mm
Voltage typeAC
Release characteristicK
Over voltage category3
Rated fault current0.3A
Current limiting class-
Surge current capacity-kA
Pollution degree2
Leakage current typeA
Frequency50/60 Hz
Connectable conductor cross section solid-coremm²
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles1
Degree of protection (IP)IP2X
Rated impulse withstand voltage Uimp-kV
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceNo
Connectable conductor cross section multi-wiredmm²
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255180R3257 | DS201 K25 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

-V

Rated current

25A

Rated voltage

230V

Built-in depth

69mm

Voltage type

AC

Release characteristic

K

Over voltage category

3

Rated fault current

0.3A

Current limiting class

-

Surge current capacity

-kA

Pollution degree

2

Leakage current type

A

Frequency

50/60 Hz

Connectable conductor cross section solid-core

mm²

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

1

Degree of protection (IP)

IP2X

Rated impulse withstand voltage Uimp

-kV

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Connectable conductor cross section multi-wired

mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.