Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current20A
Release characteristicC
Built-in depth69mm
Rated voltage230V
Voltage typeAC
Rated fault current0.03A
Rated insulation voltage Ui-V
Surge current capacity3kA
Pollution degree2
Leakage current typeOther
Frequency50/60 Hz
Width in number of modular spacings2
Degree of protection (IP)IP2X
Over voltage category3
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-coremm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Number of protected poles1
Current limiting class-
Connectable conductor cross section multi-wiredmm²
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp-kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255480R1204 | DS201 C20 APR30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

20A

Release characteristic

C

Built-in depth

69mm

Rated voltage

230V

Voltage type

AC

Rated fault current

0.03A

Rated insulation voltage Ui

-V

Surge current capacity

3kA

Pollution degree

2

Leakage current type

Other

Frequency

50/60 Hz

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Number of protected poles

1

Current limiting class

-

Connectable conductor cross section multi-wired

mm²

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

-kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.